  • 9500B series wireless high voltage CT turn ratio tester
    View More
    Current, transformation ratio, polarity and phase difference test of the transformer and current transformer primary and secondary circuits below 35kV. 1. Model No.: ETCR9500B 2. Turn Ratio Range:1~500 3. Primary Current Test Accuracy: 0.0A~800A/0.1A/ ±0.5%FS 4. Secondary Current Test Accuracy: 0.00mA~5A/0.01mA/ ±0.5%FS 5. CT Size:φ48mm & φ8mm 6. Power Supply: DC6V alkaline batteries LR03 (1.5V AAA X 8)

    Hot Tags : high voltage CT turn ratio tester wireless CT turn ratio tester wireless high voltage turn ratio tester

    View More
  • 9500C-016 series three-channel wireless high voltage CT trun ratio tester
    View More
    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9500C-016 2. Primary Current Test Accuracy : 0.0A~800A/0.1A/±0.5%FS 3. Secondary Current Test Accuracy: 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)

    Hot Tags : three channel CT turn ratio tester

    View More
  • 9500C-030 series three-channel wireless high voltage CT trun ratio tester
    View More
    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9500C-030 2. Primary Current Test Accuracy : 0.0A~800A/0.1A/±0.5%FS 3. Secondary Current Test Accuracy: 0.00mA~10A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)
    View More
  • 9550B series wireless H/L voltage CT trun ratio tester
    View More
    Measurement of primary and secondary current, transformation ratio, phase difference, polarity and phase sequence of current transformers and transformers below 35kV 1. Model No.: ETCR9550B 2. Primary Current Test Accuracy : High voltge clamp: 0.0A~800A/0.1A/±0.5%FS Flexible coil clamp: 0.0A~3000A/0.1A/±1%FS 3. Secondary Current Test Accuracy: 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Transmission Distance: Primary: 100m; Seconary: 2m cable 6. Power Supply: DC6V alkaline batteries (1.5V AAA × 8)

    Hot Tags : Low voltage CT turn ratio tester

    View More
  • 9570 series multifunction H/L voltage CT turnn ratio tester
    View More
    Turn ratio measurement; transformation ratio polarity display; voltage measurement; primary current and secondary current measurement; voltage and current waveform display; phase between primary current and secondary current, phase between each current and voltage; frequency measurement; Active power, reactive power, power factor measurement; harmonic measurement. 1. Model No.:ETCR9570 2. Voltage Range:0V~600V 3. Current Sensor Range :0A~3000A/0A~600A/ 0A~10A 4. Turn Ratio Measurement Range: 1~9999 5. Phase Range: 0~360° 6. Hot Power Supply : Lithium battery 7.4V 5200mAH

    Hot Tags : low voltage CT turn ratio tester multifunction CT turn ratio tester

    View More
  • 9600 series low voltage CT transformation ratio tester
    View More
    Online test the leakage current, current, transformation ratio, ratio error, angle error, phase and polarity of the primary and secondary circuit of the current transformer in the 380V/220V distribution system 1. Model No.:ETCR9600 2. Primary Current Test Accuracy: 0.0A~800A/ 0.1A/ ±0.5%FS 3. Secondary Current Test Accuracy : 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Communication Cable Length: 2M 6. Power Supply : Alkaline batteries (1.5V AAA × 4)

    Hot Tags : low voltage turn ratio tester CT turn ratio tester

    View More
  • 9620 series low voltage CT transformation ratio tester
    View More
    Leakage current, current, transformation ratio, ratio difference, angle difference, phase difference and polarity test of current transformer primary & secondary circuits in 380V/220V power distribution system. 1. Model No.:ETCR9620 2. Primary Current Test Accuracy: 0.0A~3000A/ 0.1A/ ±1%FS 3. Secondary Current Test Accuracy : 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Communication Cable Length: 2M 6. Power Supply : Alkaline batteries (1.5V AAA × 4)
    View More
  • 9620 series low voltage CT transformation ratio tester
    View More
    Leakage current, current, transformation ratio, ratio difference, angle difference, phase difference and polarity test of current transformer primary & secondary circuits in 380V/220V power distribution system. 1. Model No.:ETCR9620B 2. Primary Current Test Accuracy: 0.0A~3000A/ 0.1A/ ±1%FS 3. Secondary Current Test Accuracy : 0.00mA~5A/ 0.01mA/ ±0.5%FS 4. Turn Ratio Measurement Range: 1~500 5. Wireless Transmission Distance: 100M 6. Power Supply : Alkaline batteries (1.5V AAA X 4PCS & 6F22 9V X1PCS)