Wrist Type High Voltage Approach Electric Alarm, after the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the  safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope.


1. Model No.: ETCR1860

2. Alarm Voltage Range : 1kV~500kV

3. Electricity Testing Mode : Non-contact mode

4. Detection Mode : Automatic trigger

5. Max. Alarm Distance: 5.5m

6. Power Supply: CR1632(140mAH)button cell


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
  • 1860C Series Low Voltage Approach Electric Alarm
    ETCR 1860C Wrist Type Low Voltage Alarm

    After the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the  safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope. 1. Model : ETCR1860C 2. Alarm Voltage Range : 40V~1kV(Low voltage alarm) 3. Working Frequency : 50Hz/60Hz 4. Detection Mode : Automatic trigger 5. Electricity Testing Mode : Non-contact mode 6. Power Supply : CR1632(140mAH)button cell 1PCS

  • 008 series needle-nose pliers current sensor
    ETCR008 Sharp-nose type Leakage Current Sensor

    Detecting of AC leakage current, current, higher harmonic current, phase, power energy, power, power factor. 1. Model No.: ETCR008 2. Range:0.00mA~30A AC 3. Turn Ratio:2500 :1 4. Resolution: 0.01mA  AC 5. Accuracy Class: 0.5 6. Clamp Size: φ8mm

  • 6420 series clamp multimeter
    ETCR6420 Clamp Multimeter

    Measurement of  DC voltage, AC voltage, AC current true RMS, resistance, capacitance, frequency, on-off test, temperature, diode forward voltage drop and others parameters. 1. Model No.: ETCR6420 2. CT Size:Ф27mm 3. DC Voltage:0mV~600V 4. AC Voltage:0V-600V 5. AC Curent:0A-600A 6. Power Supply : LR03 X 2

  • 3800B Series Lightning Protection Component Tester
    ETCR3800B Lightning Protection Component Tester

    Applied to testing the performance parameters of the lightning protection elements such as metal oxide varistor(MOV) and  gas discharge tube (GDT) and the insulation resistance (Mohm), polarization index (PI), dielectric absorption ratio (DAR). 1.Model No.:ETCR3800B 2. Initial action voltage test,Range:50~3000V 3. Leakage Current ,Range:0~1000μA 4 .DC breakdown voltage test,Range:50~3000V 5 .Insulation resistance Mohm test:Range:0.5~10GΩ 6. Power Supply : DC 7.4V 2600mAH rechargeable lithium battery

  • 3500B Series High Voltage Insulation Resistance Tester
    ETCR3500B High Voltage Insulation Resistance Tester

    Suitable for insulation resistance testing of cable, motor, generator, transformer, mutual inductor, high voltage switch, arrester and other large equipment.Insulation resistance test (IR); polarization index test (PI); Dielectric absorption ratio test (DAR); Step test(STEP); Ramp test (RAMP).AC/DC Voltage test(V) 1.Model No.:ETCR3500B 2. Insulation Resistance Range: 0.005MΩ~10.0TΩ 3. Rated Voltage: 50v~10Kv(7 gears) 4. Shout Circuit Current: >5mA MAX 5. Custom Setting Voltage :AC/DC 0V~1000V 6. Power Supply : Rechargeable lithium battery pack 5.2Ah 14.8v

  • 9100 series H/L voltage clamp current meter
    ETCR9100 H/L Voltage Clamp Current Meter AC 0.00mA~600A

    H/L voltage AC leakage current and current measurement below 60KV. (Above 600V operate with insulation rods). 1. Model No.: ETCR9100 2. Current Range: AC 0.00mA~600A 3. Resolution: 0.01mA 4.CT Size: φ33mm 5. Line Voltage: Below 60kV current test , operate with insulation rods 6. Power Supply: 6VDC (LR03 × 4pcs alkaline dry batteries)

  • 1000d series non-contact phase sequence detector
    ETCR1000D Non-contact Phase Sequence Detector

    Phase sequence detection (positive phase, anti-phase, default phase), live line inspection, simple electrical inspection, fire line identification, default phase judgment, broken line location search, DC line breakpoint detection, line maintenance. 1. Model No.: ETCR1000D 2. Test Method: Non-contact type 3. Live Electricity Range: AC 70~1000V 4. Frequency Range: 45~65Hz 5. Clamp Wire Diameter: Φ10~Φ40mm 6. Power Supply: DC 3V AA alkaline batteries (LR6)×2PCS

  • 040A Series Clamp Current Sensor
    ETCR040A Clamp Current Sensor 500A

    Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Model No.: ETCR040A 2. Range :0.00A~500A 3. Turn Ratio/Output Voltage : 4000:1 /0~3V(20Ω) 4. Resolution : 0.01A 5. Accuracy Class :0.5 6. Clamp Size :35mm×40mm

Top
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
  • Home

    Products

    skype

    whatsapp