Products
Home / Products /

High Voltage Electroscope

/

H/L Voltage Alarm(Wrist Type)

/ETCR1860 Wrist Type High Voltage Alarm

ETCR1860 Wrist Type High Voltage Alarm

Wrist Type High Voltage Approach Electric Alarm, after the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the  safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope.


1. Model No.: ETCR1860

2. Alarm Voltage Range : 1kV~500kV

3. Electricity Testing Mode : Non-contact mode

4. Detection Mode : Automatic trigger

5. Max. Alarm Distance: 5.5m

6. Power Supply: CR1632(140mAH)button cell


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
  • 1860C Series Low Voltage Approach Electric Alarm
    ETCR 1860C Wrist Type Low Voltage Alarm

    After the operator wears the alarm, and close to the high voltage charged body for a certain distance, the alarm will send out a sound and light alarm according to the  safety distance of the corresponding voltage level to remind the electrical worker to pay attention to safety and avoid high voltage electric shock accident. This product can also be used for line fault detection and electroscope. 1. Model : ETCR1860C 2. Alarm Voltage Range : 40V~1kV(Low voltage alarm) 3. Working Frequency : 50Hz/60Hz 4. Detection Mode : Automatic trigger 5. Electricity Testing Mode : Non-contact mode 6. Power Supply : CR1632(140mAH)button cell 1PCS

  • 030A Series Clamp Current Sensor
    ETCR030A Clamp Current Sensor 300A

    Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Range :0.00A~300A 2. Turn Ratio/Output Voltage : 3000:1 /0~3V(30Ω) 3.  Resolution : 0.01A 4.  Accuracy Class : 0.5 5. Safety class : CATⅢ600V 6. Clamp Size :25mm×30mm

  • 3520C Series High Performance HV Insulation Resistance Tester
    ETCR3520C High Performance HV Insulation Resistance Tester

    Suitable for insulation resistance testing of cable, motor, generator, transformer, mutual inductor, high voltage switch, arrester and other large equipment. Insulation resistance measurement (IR); polarization index measurement (PI); dielectric absorption ratio (DAR); ramp test mode (RAMP); Filtered resistance test mode (FR). Voltage test(V); capacity test(uF); current test(nA) 1. Model No.:ETCR3520C 2. Insulation Resistance Range: 0.5MΩ~30TΩ 3. Rated Voltage: 250v~15Kv(7gears) 4. Shout Circuit Current: ≥7mA MAX 5. VoltageTest Range: AC/DC 0V~1000V 6. Power Supply : Rechargeable lithium battery pack 6.2Ah 14.8V

  • 3200C Series Double Clamp Earth Resistance Tester
    ETCR3200C Double Clamp Earth Resistance Tester

    With 4-wire method,3-wire method and simple 2-wire method, selection method, double clamp methodto measureearth resistance,DC currentsoil resistivity,earth voltage, AC voltage,grounding lead leakage current. 1. Model No.: ETCR3200C 2. 2/3/4-wire method measure earth resistance,Range: 0.00Ω ~ 30.00kΩ 3. Selection method meausre earth resistance, Range: 0.00Ω ~ 3000Ω 4. Doule clamp method measure earth resistance,Range: 0.00Ω~100Ω 5. Soil resistivity measurement, Range: 0.00Ωm ~ 9000kΩm 6. Earth voltage measurement,Range: AC 0.0 ~ 100.0V

  • 080A Series Clamp Leakage Current Sensor
    ETCR080A Clamp Leakage Current Sensor 1000A

    Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Model No.: ETCR080A 2. Range : 0.00A~1000A 3. Turn Ratio/Output Voltage:2000:1 / 0~3V(6Ω) 4. Resolution : 0.01A 5. Accuracy Class : 0.5 8. CT Size:80mm x 80mm

  • 8042 series wireless clamp current monitor
    ETCR8042/ETCR8042A Wireless Clamp Current Monitor

    The clamp current monitor use wireless communication to upload test data to concentrator or server for real-time monitoring of current, leakage current, troubleshooting of circuit insulation fault, monitoring of intermittent leakage fault, checking the time of insulation fault and fault location, etc. 1. Model No.: ETCR8042/ETCR8042A 2. Range :  AC 0.0mA~300.0A/AC 0mA-600A 3.  Clamp Size : Φ40mm 4. Communication Mode: GPRS communication mode or GSM 4G network 5. Sampling Frequency : 1 times/second 6. Power Supply : 3300mAH

  •  2800C  Series Non-Contact Earth Resistance On-line Detector
    ETCR 2800C Non-Contact Earth Resistance On-line Detector

    On-line monitoring of grounding resistance and metal loop coupling resistance, grounding condition monitoring 1. Model No.: ETCR2800C 2. Test Mode: Non-contact type 3. Communication Mode: RS485 or GPRS communication (optional) 4. Resistance Range: 0.01Ω~200Ω; 5. Accuracy: ±2%rdg±3dgt(20℃±5℃,Below70%RH) 6.Power Supply: 6VDC~12VDC, 50mA Max.

  • 2000C+ Series Clamp Earth Resistance Tester
    ETCR2000C+ Clamp Earth Resistance Tester

    Earth resistance measurement, loop resistance measurement, grounding down leads leakage currentmeasurement, judge groundfault. 1. Model No.: ETCR2000C+ 2. Resistance Measure Range: 0.010Ω~1200Ω 3. Leakage Current Measure Range: 0.00mA~20.0A 4. Alarm Threshold Setting: 1-199Ω 5. Alarm Function: audible and visible alarm 6. Power Supply : 6VDC ( 4 PCS of No.5 LR6 Alkaline dry batteries)