Products
Home / Products /

Phase/Phase Sequence Detector

/

Phase Sequence Detector

/ETCR1000D Non-contact Phase Sequence Detector

ETCR1000D Non-contact Phase Sequence Detector

Phase sequence detection (positive phase, anti-phase, default phase), live line inspection, simple electrical inspection, fire line identification, default phase judgment, broken line location search, DC line breakpoint detection, line maintenance.


1. Model No.: ETCR1000D

2. Test Method: Non-contact type
3. Live Electricity Range: AC 70~1000V
4. Frequency Range: 45~65Hz
5. Clamp Wire Diameter: Φ10~Φ40mm
6. Power Supply: DC 3V AA alkaline batteries (LR6)×2PCS



Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
  • 1050 series
    ETCR1050 Wireless High Voltage Phase Sequence Detector

    Apply to phase sequence detection, phase testing, phase detecting and electricity testing of power high-voltage lines below 500kV. 1. Model : ETCR1050 2. Phase Detecting Voltage : AC 10V~500kV 3. Phase Detecting Distance : 200m 4. Phase Range : 0°~360° 5. Frequency Range : 45.0Hz~65.0Hz

  • 1000c series non-contact phase sequence detector
    ETCR1000C Non-contact Phase Sequence Detector

    Phase sequence detection (positive phase, anti-phase, default phase), live line inspection, simple electrical inspection, fire line identification, default phase judgment, broken line location search,DC line breakpoint detection, line maintenance 1. Model : ETCR1000C 2. Available Clamp Wire Size : ø1.6mm-ø16mm 3. Live Power Range : AC70-1000V, 45-65Hz (Sine Wave Continuous Input) 4. AutoShutdown : 5 minutes after booting up, the meter automatically shutdown 5. Insulation Strength : 5.4kV/rms 6. Power Supply : DC 3V AA alkaline batteries (LR6)×2PCS

  • 1560A Series Multifunctional Satellite Remote Wireless Phase Detector
    ETCR1560A Multifunctional Satellite Remote Wireless Phase Detector

    Applied toremote and shouting distancephase detecting, phase testing, phase sequence judgement and electrictity testing of the high voltage line,metalclad withdraw switchgear and ring main unit and others occasion. 1. Model : ETCR1560A 2. Phase Qualitative: Same phase:-20°~20°;Out of phase: 100°~140° and 220°~260° 3. Phase Range & Accuracy : 0°~360°;Accuracy:≤±8 ° 4. Frequency Range & Accuracy: 45.0Hz~65.0Hz;Accuracy:≤±2Hz 5. Transmitting Frequency : 433MHz, 315MHz 6. Host Power Supply : 3.7V, 2600mAh Rechargeable lithium battery

  • 016 Series Clamp Leakage Current Sensor
    ETCR016 Clamp Leakage Current Sensor 20A

    Measurement of AC leakage current, phase, power energy, power, power factor, harmonicetc. Apply to oscilloscope, harmonic analyzer, power fault analyzer and other industrial control devices. 1. Model No. : ETCR016 2. Range : 0.00mA~20A 3. Accuracy Class : 0.5 4. Turn Ratio : 800:1 5. Frequency : 10Hz~100kHz 6. Clamp Size : φ16mm

  • 1050 series
    ETCR1050 Wireless High Voltage Phase Sequence Detector

    Apply to phase sequence detection, phase testing, phase detecting and electricity testing of power high-voltage lines below 500kV. 1. Model : ETCR1050 2. Phase Detecting Voltage : AC 10V~500kV 3. Phase Detecting Distance : 200m 4. Phase Range : 0°~360° 5. Frequency Range : 45.0Hz~65.0Hz

  • 010K series split type high accuracy leakage current sensor
    ETCR010K Split Type High Accuracy Leakage Current Sensor

    Measurement of AC leakage current, higher harmonic current, phase, power energy, power factor. 1. Model No.: ETCR010K 2. Range:0.00mA~20A AC 3. Turn Ratio:800:1 4. Resolution:  0.01mA AC 5. Accuracy Class: 0.5 6. Safety Class:  CATⅢ600V

  • 080A Series Clamp Leakage Current Sensor
    ETCR080A Clamp Leakage Current Sensor 1000A

    Detecting of AC current, phase, power energy, power, and power factor, harmonic etc. Apply to oscilloscope, harmonic analyzer, Power fault analyzer and other industrial control devices 1. Model No.: ETCR080A 2. Range : 0.00A~1000A 3. Turn Ratio/Output Voltage:2000:1 / 0~3V(6Ω) 4. Resolution : 0.01A 5. Accuracy Class : 0.5 8. CT Size:80mm x 80mm

  • 9000A series H/L voltage clamp current meter (bluetooth)
    ETCR9000A H/L Voltage Clamp Current Meter (Bluetooth)

    Measurement of H/L voltage AC current below 110kV. (Above 600V, operate with insulation rod). 1. Model No.: ETCR9000A 2. Measurement range: AC 0mA~1200A ; 3. Max resolution : 1mA; 4. CT Size: Ф48mm; 5. Communication mode: bluetooth, straight distance 10m ; 6. Power Supply : Ablelithium battery DC 7.4V 600mAH