ETCR080K Split Type High Accuracy Leakage Current Sensor, suitable for high precision AC leakage current, current, high harmonic current, phase, power, power, power factor and other detection. Range: 0.00mA~60A, jaw size is Φ80mm. The sensor adopts the Split CT structure, which can be installed without disconnecting the tested circuit. It is especially suitable for online use. It adopts permalloy iron core and double shielding technology, and has strong anti-interference ability to ensure the accuracy and stability of measurement. Non-contact measurement methods are adopted, and the operation is safe and simple. It can be connected to phase detection analyzers, industrial control devices, data recorders, oscilloscopes, harmonic analyzers, power quality analyzers, and high-precision digital multimeters.
Specification
Technical Parameter
Function
Description
Function
AC leakage current、higher harmonic current、phase、power energy、power、power factor measurement etc.
Detection Method
Split type structure design, no need to interrupt the power supply and disconnect the circuit in testing,especially suitable for online installation
Measurement of AC leakage current, higher harmonic current, phase, power energy, power factor. 1. Model No.: ETCR010K 2. Range:0.00mA~20A AC 3. Turn Ratio:800:1 4. Resolution: 0.01mA AC 5. Accuracy Class: 0.5 6. Safety Class: CATⅢ600V
Measurement of AC leakage current, higher harmonic current, phase, power energy, power factor. 1. Model No.:ETCR025K 2. Range:0.00mA~30A AC 3. Turn Ratio:800:1 4. Resolution: 0.01mA AC 5. Accuracy Class: 0.5 6. CT Size: Φ25mm
Measurement of AC leakage current, higher harmonic current, phase, power energy, power factor. 1. Model No.:ETCR040K 2. Range:0.00mA~60A AC 3. Turn Ratio:800:1 4. Resolution: 0.01mA AC 5. Accuracy Class: 0.5 6. CT Size: Φ40mm
Detection of AC leakage current, higher harmonic current, phase, power factor etc. Lightning arrester and insulator on-line detecting 1. Model No.: ETCR022KU 2. Range: 0.000mA~10A AC 3. Turn Ratio:1000:1 4. Resolution: 1uA AC 5. Accuracy Class: 0.5 6. CT Size:Φ22mm
On-line detecting of DC leakage current. 1. Model No.: ETCR010KD 2. Range: 0.0mA~100mA 3. Resolution: 0.1mA 4. Accuracy Class: 3.0 5. Signal Output : 50mV/1mA 6. Power Supply: ±12V DC
On-line detecting of DC leakage current. 1. Model No.: ETCR025KD 2. Range: 0.0mA~100mA 3. Resolution: 0.1mA 4. Accuracy Class: 3.0 5. Signal Output : 50mV/1mA 6. Power Supply: ±12V DC
Detection of AC leakage current, higher harmonic current, phase, power factor etc. Lightning arrester and insulator on-line detecting 1. Model No.: ETCR045KU 2. Range: 0.000mA~10A AC 3. Turn Ratio:1000:1 4. Resolution: 1uA AC 5. Accuracy Class: 0.5 6. CT Size:Φ45mm
Detection of AC leakage current, higher harmonic current, phase, power factor etc. Lightning arrester and insulator on-line detecting 1. Model No.: ETCR080KU 2. Range: 0.000mA~10A AC 3. Turn Ratio:1000:1 4. Resolution: 1uA AC 5. Accuracy Class: 0.5 6. CT Size:80mm X 20mm