ETCR EM1860 Wrist Type High Voltage Approach Electricity Alarm
  • Product Series : Wrist Type Approach Electricity Alarm

    • Main Features

      After the operator wearing the alarm, when approaching the certain distance from the high voltage charged object,the alarm will emit sound and light alarm according to the safe distance corresponding to the voltage level, reminding the electrical worker paying attention to safety and avoiding high-voltage electric shock accident.This product can also be used for line fault detection and electroscope use.
      Alarm voltage range: 1kV~500kV
      Method of electricity verification: non-contact
      Protection level: IP54
      Sound and light alarm

    Product Introduction

    ETCR EM1860 Wrist Type High Voltage Approach Electricity Alarm, also known as wearable near-electric alarm, which provides a safe, practical and convenient new-type high voltage alarm device for near-electric operators. When work on electric device without turning off electricity, the safety distance between the operator and the live object should not be lower than the requirement of relevant work regulation. After the operator wearing this alarm, when approaching the certain distance from high voltage live object, the alarm will emit sound and light alarm according to the corresponding safety distance of the voltage level, reminding electrical worker paying attention to safety and avoiding high voltage electric shock accident.


    ETCR EM1860 Series Wrist Type High Voltage Approach Electricity Alarm has two options: high voltage alarm (suitable for 1kV and above) and low voltage alarm (suitable for 1kV and below), adopting with non-contact induction technology, accurate alarm, energy-saving and durable, with standby time up to 12 months. The alarm has unique automatic triggering detection function to ensure the safety of live working personnel. This alarm are widely used in near-electric workplaces such as power, railway and industrial mining enterprise.


    1.The alarm is worn on the wrist of the operator.
    2.Adopt with non-contact induction technology, accurate alarm, energy-saving and durable, with standby time up to 12 months.
    3.Comprehensive detects the electric field in the air in all directions, trigger automatically alarm function, sound and light mode, ensuring the safety of near-electricity operator.
    4.Protection level: IP54

    EM1860 (5).jpg


    Technical Parameters

    1.Voltage level and alarm distance (safety distance according to "GB 26860-2011 Electric Power Safety Work Regulations - Electrical Part of Power Plants and Substations" and "GB 26859-2011 Electric Power Safety Work Regulations - Power Line Part")

    Voltage LevelSafety DistanceAlarm Distance
    1kV
    0.10m
    6.6kV
    0.70m
    10kV0.70m1.00m
    35kV1.00m1.60m
    66kV1.50m2.20m
    110kV1.50m2.50m
    220kV3.00m3.50m
    330kV4.00m4.50m
    500kV5.00m5.50m

     
    2.General Specifications

    Power SupplyCR1632 (140mAH) button cell 1 PCS
    Alarm Voltage Range1kV~500kV (high voltage alarm)
    Work Frequency50Hz/60Hz
    Method Of Electricity VerificationNon-contact
    Detection ModeAutomatic trigger
    Alarm Distance Error±10cm (Under benchmark conditions)
    Battery LifeContinuous operation (sound and light alarm): about 24 hours
    Standby time: about 12 months
    Alarm MethodIndicator light: 8000LX visible light visible LED light
    Buzzer: Above 60dB (60cm apart)
    Protection LevelIP54
    Overall Size90mm×40mm×35mm
    WeightMeter: 40g (include battery); Total:0.08kg (include accessories)
    Working Temperature & Humidity-10℃~40℃; below 80%RH
    Storage Temperature & Humidity-10℃~60℃; below 70%RH


    Model Comparison

    Product PictureProduct Model NameVoltage RangeSound & Light AlarmPower Supply ModeStandby Time
    EM1860 (1).jpgETCR EM1860 Wrist Type High Voltage Approach Electricity AlarmAC 1kV~500kVYesButton cell12 months
    EM1860C (1).jpgETCR EM1860C Wrist Type Low Voltage Approach Electricity AlarmAC 40V~1kVYesButton cell12 months
    EM1870 (1)~1.jpgETCR EM1870 Arm Type High Voltage Approach Electricity AlarmAC 1kV~500kVYesButton cell12 months
    EM1870C (1)~1.jpgETCR EM1870C Arm Type Low Voltage Approach Electricity AlarmAC 40V~1kVYesButton cell12 months
    EM1880 (1)~1.jpgETCR EM1880 Helmet High Voltage Approach Electricity AlarmAC 1kV~500kVYesButton cell12 months
    EM1880C (1)~1.jpgETCR EM1880C Helmet Low Voltage Approach Electricity AlarmAC 40V~1kVYesButton cell12 months


    Product Video

    Related Products
    ETCR EM1860 Wrist Type High Voltage Approach Electricity Alarm
    ETCR EM1860C Wrist Type Low Voltage Approach Electricity Alarm

    Friendly Links

      Contact Us

    86 757 66860936

    [email protected]

    10th Floor, Block 5, Liandong Intelligent Manufacture Park, No. 105, Shilong North Road, Nanhai District, Foshan City, Guangdong, China

    All Rights Reserved © Guangdong ETCR Electronic Technology CO.,Ltd 2025
    Site Map
    Independent Station

    Home
    Tel
    Product
    Contact