Product Series : Transformer Core Earth Current Tester
Used for transformer core grounding current test, AC leakage current, current, and frequency online test
Jaw size: 80mm×80mm
Current range: AC 0.00mA~100A
Frequency range: 10Hz~1000Hz
Alarm function, alarm threshold can be set
Storage function, store 200 sets of data
USB communication interface
Product Introduction
ETCR EM8100B Transformer Core Earth Current Tester, also known as transformer core grounding parameter tester and grounding current tester, is used to test the grounding current and leakage current of transformer core in power systems.The instrument consists of a host, a current clamp, monitoring software, a communication line, etc.Power transformers are important electrical equipment in the power system. Once they fail in operation, they will have serious consequences for the power system.The core of the transformer in normal operation is grounded at a single point. If two or more points are grounded at the same time, a current loop will be formed between the core and the earth, with a maximum current of tens of amperes, which will cause the core to overheat or even burn down.This instrument can detect latent faults of the transformer as soon as possible, and is the main tool to ensure the safe operation and normal maintenance of the transformer.The instrument has anti-interference ability and can be applied to use in an environment with strong magnetic field interference next to the transformer.It is mainly suitable for leakage current testing of iron cores and clamps of electrical equipment such as transformers and reactors in substations and power plants.It can also be used for current and leakage current testing of lines or equipment in the fields of electric power, communications, meteorology, railways, oil fields, construction, metrology, scientific research and teaching units, industrial and mining enterprises, etc.
ETCR EM8100B Transformer Core Earth Current Tester adopts a high-speed microprocessor, a 3.5-inch color touch LCD screen, and a Chinese interface for easy and fast operation.It can display the size and waveform of the measured current in real time; it has the function of setting the alarm threshold value and alarm indication; it has the function of date clock and setting; it has the function of automatic shutdown; it has the function of setting the test product number; it has a USB interface, which can import the stored data into the computer, and the instrument can store 200 sets of data and waveforms.
1. It is mainly suitable for leakage current testing of iron cores and clamps of electrical equipment such as transformers and reactors.Being able to detect latent faults of transformers in a timely manner is the main tool to ensure the safe operation and normal maintenance of transformers.
2. The current clamp adopts permalloy iron core and double-layer shielding technology, with stable performance and high precision, strong anti-interference ability, and is suitable for complex interference environments.
3. Alarm function, the alarm threshold can be set.
4. Storage function, storing 200 sets of data.
5. Number setting function.
6. USB communication interface.
Technical Parameters
Power Supply | DC 9V alkaline dry battery LR6 1.5V×6 |
Display Mode | 3.5inch color touch LCD screen (320dots×240dots) |
LCD Size | Display area: 71mm×53mm |
Test Method | Clamp CT |
Clamp Jaw Size | 80mm×80mm (can clamp Φ80mm wire, or 96mm×4mm flat steel ground wire) |
Current Range | AC 0.00mA~100A |
Resolution | AC 0.00mA~0.99mA; resolution: 0.01mA; |
AC 1.0mA~99.0mA; resolution: 0.1mA; | |
AC 100mA~999mA; resolution: 1mA; | |
AC 1.0A~100.0A; resolution: 0.1A; | |
Accuracy | ±(0.5%+5dgt) 23℃±3℃, below 70%RH, the wire is in the center of the jaw |
Frequency Range | 10Hz~1000Hz |
Operation Method | At the same time, it has intelligent touch and button control methods |
Host Size | 198mm×100mm×45mm |
Current Clamp Size | 194mm×145mm×40mm |
Weight | Host: 450g (including battery); current clamp: 780g |
Electric Field Interference | When the external electric field 100A is close to 10mm, it is about 10mA |
Sampling Rate | 1 time/second |
Memory | 200 sets (no data will be lost if the battery is powered down or replaced) |
Date Clock | With date clock and setting function |
Test Product Number | Has the function of setting the test point number |
Automatic Shutdown | It has the function of setting the function of automatic shutdown and non-automatic shutdown, and it will automatically shut down after 5 minutes by default when it is turned on. |
Touch Screen Calibration | With touch screen calibration function |
USB Communication Interface | With a USB interface, the data stored in the instrument can be imported into the computer |
Alarm Setting | Alarm threshold setting range: 10mA~99.99A |
Alarm Indication | When the test value exceeds the alarm threshold value, the LCD flashes and the buzzer sounds. |
Line Voltage | Line test below AC 600V |
Overflow Display | Over-range overflow function: ”OL" symbol display |
Battery Voltage | When the battery voltage drops to 7.2V±0.1V, the low battery voltage symbol is displayed to remind the battery to be replaced. |
Rated Current | Maximum 180mA |
Insulation Strength | AC 2kV/rms (between screw and housing) |
Suitable Safety Standard | IEC1010-1, IEC1010-2-032, pollution level 2, CAT Ⅲ600V, IEC61326 (EMC standard) |
Working Temperature & Humidity | -10℃~40℃; below 80%rh |
Storage Temperature & Humidity | -10℃~60℃; below 70%rh |
Model Comparison