    EM1880E Helmet High Voltage Approach Electricity Alarm
  • Product Series : Wearable Proximity Alarm

    • Main Features

      When workers wear the alarm device, if they come within a certain distance of a high-voltage live conductor, the device emits an audible and visual alarm based on the safety distance corresponding to the voltage level, reminding electrical workers to exercise caution and prevent high-voltage electric shock accidents.
      Alarm Voltage Range: 0.4 kV ~ 500 kV
      Alarm Current Range: 1 A ~ 200 A
      Operating Frequency: 50 Hz/60 Hz
      Voltage Detection Method: Non-contact
      Standby Time: 7 days
      Protection Rating: IP65
      Power Supply: 3.7 V DC, 350 mAh lithium battery
      Audible and Visual Alarms

    Product Introduction

    EM1880E Safety Helmet High-Voltage Proximity Alarm provides workers performing live-line operations with a safe, practical, and convenient new type of high-voltage proximity alarm device. When working on live lines, the safety distance between the operator and live parts must not be less than the requirements specified in relevant work procedures. When workers wear this alarm, it triggers audible and visual alerts upon approaching a high-voltage live conductor within a certain distance—based on the safety distance corresponding to the voltage level—to remind electrical workers to exercise caution and prevent high-voltage electric shock accidents. The alarm is widely used in high-voltage work environments such as the power industry, railways, and industrial and mining enterprises.

    EM1880E Safety Helmet High-Voltage Proximity Alarm features two detection and alarm modes: voltage detection (monitoring electric fields) and current detection (monitoring magnetic fields). It utilizes non-contact sensing technology to comprehensively monitor overhead electric and magnetic fields, with a voltage detection range of 0.4 kV to 500 kV and a current detection range of 1 A to 200 A. Both detection modes are enabled simultaneously, and an alarm is triggered when values exceed the alarm threshold. When a voltage alarm is triggered, the LED strip lights up red; when a current alarm is triggered, the LED strip lights up blue, providing users with more comprehensive and safer protection. The alarm also features self-testing, adjustable alarm sensitivity, a mute function, progressive alarm indication, and voltage source direction indication. The alarm also features Bluetooth connectivity, allowing users to adjust alarm sensitivity, check battery level, and view alarm parameters via Bluetooth. The alarm is energy-efficient and durable, with a standby time of up to 7 days on a full charge. It attaches to the brim of a safety helmet using two elastic clips; its anti-slip design ensures a secure fit, and it is very easy to install or remove.


    Product Features

    1. Non-contact sensing technology: Monitors electric and magnetic fields in the air from all directions, with high alarm sensitivity.

    2. Two detection and alarm modes: Voltage detection and current detection, providing users with more comprehensive and safer protection.

    3. Self-test function: Continuously checks whether the alarm is operating normally.

    4. Alarm Sensitivity Settings: Three adjustable levels—Low, Medium, and High—to accommodate use in complex electric field environments.

    5. Silent Mode: Prevents alarm sounds from causing interference in environments with strong electric fields.

    6. Progressive Alarm Indication: Alerts workers to their distance from live conductors via the flashing frequency of the LED light bar and the beeping frequency of the buzzer.

    7. Voltage Source Direction Indication: The LED strip indicates the direction of the voltage source (for voltage detection only).

    8. Battery Level Check: The battery level can be checked via the LED strip upon completion of the self-test.

    9. Low Battery Alert: When the battery level drops below one bar, one LED on the LED strip flashes green to remind the user to recharge the alarm promptly.

    10. Bluetooth Communication: Allows for sensitivity adjustment and viewing of alarm parameters.

    11. Equipped with a shielded carrying case; placing the alarm inside the case prevents it from triggering an alarm.

     EM1880E (9).jpg EM1880E (10).jpg

    Technical Parameters

    Specification NameParameters Description
    Power SupplyLithium battery DC 3.7V, 350mAh
    Detection MethodNon-contact
    Detection & Alarm ModesVoltage detection: monitors the air electric field; Current detection: monitors the air magnetic field
    Alarm Voltage Range0.4 kV – 500 kV
    Alarm Current Levels1 A – 200 A
    Operating Frequency50 Hz / 60 Hz
    Alarm IndicationLED strip: red flashing (voltage alarm), blue flashing (current alarm); Buzzer: 60 dB (at 60 cm distance)
    Self-test FunctionVerifies that the alarm is operating normally
    Sensitivity Levels3 adjustable levels — weak, medium, strong; the LED strip shows the current level while setting
    Progressive Alarm IndicationThe LED flashing rate and buzzer beeping rate indicate alarm intensity
    Voltage Source Direction IndicationLED strip lights up red to indicate the direction of the voltage source (voltage detection only)
    Silent ModeAvoids buzzer sound interference in strong electric field environments
    Standby Time7 days when fully charged
    Protection RatingIP65
    Battery Level IndicationAfter self-test, the LED strip shows green to indicate battery level
    Low Battery IndicationWhen only 1 bar remains, the leftmost LED on the strip flashes green to remind the user to recharge
    Bluetooth CommunicationUsed for alarm parameter settings and viewing alarm information
    Alarm Dimensions85 mm × 35 mm × 23 mm
    Alarm WeightApprox. 0.22 kg (including accessories)
    Operating Temperature & HumidityOperation: -10°C to 40°C, below 80% RH; Storage: -10°C to 60°C, below 70% RH
    Standard AccessoriesAlarm ×1; Power adapter ×1; Charging cable ×1; Tool kit ×1


    Model Comparison

    Product ModelAlarm Voltage RangeStandby TimeProtection LevelAlarm Method

    EM1870 (1).jpg

    EM1870
    1kV~500kV12 monthsIP54Sound & Light Alarm

    1870C.png

    EM1870C
    40V~1kV12 monthsIP54Sound & Light Alarm

    EM1880 (1).jpg

    EM1880
    0.4kV~500kV12 monthsIP54Sound & Light Alarm

    1880C.png

    EM1880C
    40V~1kV12 monthsIP54Sound & Light Alarm

    1880E.png

    EM1880E
    0.4kV~500kV7 daysIP65Sound & Light Alarm


    Product Video

    Related Products
    EM1860P Wristwatch-style proximity alarm
    EM1880E Helmet High Voltage Approach Electricity Alarm
    EM1860A Wrist-Worn Proximity Alarm
    EM1860 Wrist Type H/L Voltage Proximity Alarm
    EM1860AC Wrist-Worn Electrical Hazard Alarm (Low Voltage)
    EM1860C Wrist Type Low Voltage Approach Electricity Alarm
    • Contact Us

    +86 13802922567 (Johnson Zhang)

    [email protected]

    +86 13809214246 (Wendy Wong)

    [email protected]

    10th Floor, Block 5, Liandong Intelligent Manufacture Park, No. 105, Shilong North Road, Nanhai District, Foshan City, Guangdong, China

    All Rights Reserved © Guangdong ETCR Electronic Technology CO.,Ltd 2025 1
    Site Map
    Independent Station

    Home
    Tel
    Product
    Contact